Power 101: Flue Gas Heat Recovery in Power Plants, Part I

Apr 01, 2010 · The acid dew point temperature is presented in Figure 4 as a function of the SO 3 and H 2 O concentration in the flue gas. Sulfuric acid condenses as temperature is decreased bellow the dew point

Get A Quote

Flue gas heat recovery through the acid dew point

The acid dew point temperature depends on the levels of reactants present in the flue gas. It generally lies in the range 100-150°C. Figure 1 shows the relationship between the ADP and the SO3 level, calculated at a typical H2O level of 15 vol% by using a number of different approaches proposed in …

Get A Quote

Flue gas heat recovery through the acid dew point

The acid dew point temperature depends on the levels of reactants present in the flue gas. It generally lies in the range 100-150°C. Figure 1 shows the relationship between the ADP and the SO3 level, calculated at a typical H2O level of 15 vol% by using a number of different approaches proposed in …

Get A Quote

Get acid dew point of flue gas (Journal Article) | OSTI.GOV

In boiler operation, heat loss to flue gases amounts to as much as 20 to 25% of the heat input. To recover heat from flue gases, economizers are generally used to preheat boiler make-up water or forced draft combustion air. The dew point usually limits the practical lower temperature of …

Get A Quote

Boiler modulation – is more better? - HPAC Magazine

Feb 23, 2018 · When enough thermal energy from the hot gases is transferred to the boiler water the overall hot gas temperature dips below the water dew point and some or all of the water becomes liquid. The energy released when water converts from a vapour to a liquid is picked up by the boiler water and results in a significant boost in efficiency.

Get A Quote

Fuels Flue Gases and Average Dew Points

anthrasite. bituminous. manufactured gas. natural gas. oil. semi-bitumius. are indicated in the charts below. Flue Gases - Average Dew Point for Typical Fluids (pdf) Excess air is the ratio of air supplied to the combustion process to what is theoretically required for perfect combustion ( stoichiometric combustion ).

Get A Quote

What is dew point? | Viessmann

Different Types of Corrosion: Dew Point Corrosion -Causes and

Get A Quote

Temperature control in condensing and non condensing

Conventional boiler. A high return water temperature gives you safe operation. But make it too high and efficiency suffers. A shunt in a conventional boiler keeps the return water temperature above the flue gas dew point, avoiding corrosion and thermal shock.

Get A Quote

Efficiency factors in natural gas fired steam boilers

The main parameters that affect a steam boiler's efficiency are boiler load, combustion air, stack gas temperature, radiant heat loss, and acid dew point. In this article, natural gas fired conventional steam boilers are evaluated and potential savings are determined in the power plant of Tüpraş İzmir refinery.

Get A Quote

Low-Temperature Boiler Corrosion and Deposits—A Literature

Corrosion Behavior of a Ni–Cr–Mo Alloy Coating Fabricated by Laser Cladding in a Simulated Sulfuric Acid Dew Point Corrosion Environment. Coatings 2020, 10 (9), on dew point corrosion characteristics of the heating surface in a 65 t/h biomass-fired circulating fluidized bed boiler. Applied Thermal Engineering 2016, 96, 76-82.

Get A Quote

Modelling the thermal efficiency of condensing boilers

boiler, below the dew point (52°C), the efficiency gradually rises and sharply increases below until 106%. The trend is the same for the fuel oil boiler. In this case, the dew point temperature is lower (47°C). Below the dew point, the efficiency rises until 104%. Calculated thermal efficiency has been compared to the measured one for each test.

Get A Quote

Investigation of the Concepts to Increase the Dew Point

The dew point of the byproducts created when burning natural gas is around 55 ℃. Therefore, in order for the boiler to work as efficiently as possible in condensing mode, the surface of the heat exchanger should not exceed this temperature. This is because this is the temperature at which water droplets could form.

Get A Quote

RAJ WASTE HEAT RECOVERY BOILERS DESIGN AND DRAFTING

Acid dew point corrosion 1.Takes place in cold end of boiler (Eco.APH) whose metal temperature is less than sulphur dew point temperature. Floating roof storage tanks is used only high vapour everopration, this tanks construction cost is high compere to the fixed roof storage tanks for more details click storage tank design

Get A Quote

Consulting - Specifying Engineer | Controlling dew point

Aug 21, 2009 · H2O + SO3 → H2SO4 Depending upon the ppm of SO3 and water-vapor concentration, the dew point temperature can vary from around 90 degree centigrade to 140 degree centigrade. Condensation of these acids results in metal wastage and boiler tube failure, air preheater corrosion, and flue gas duct corrosion.

Get A Quote

Combustion Efficiency and Excess Air

The combustion efficiency increases with increased excess air - until the heat loss in the excess air is larger than the heat provided by more efficient combustion. Typical excess air to achieve the highest possible efficiency for some common fuels: 5 - 10% for natural gas. 5 - 20% for fuel oil.

Get A Quote

Increase in the boiler's performance in terms of the acid

May 01, 2008 · On the one hand, this paper compares the effects of the acid dew point temperature (ADT) on pre-heaters in a reference thermal power plant for two types of fuel, "fuel No. 2" and "low sulphur fuel" respectively and on the other hand, it shows how a changeover to this latter fuel would increase the useful lifetime of this equipment

Get A Quote

Maximizing Boiler Plant Efficiency

• Thermal Efficiency – The combustion efficiency minus 2% = Lower dew point temperature Lower dew point temp. = Less condensation . 3/20/12 Condensing Boilers 21 Higher CO 2 =Higher Dew point =More Condensation 77 86 95 104 113 122 131 140 oF oC 25 30 35 40 45 50 55 60

Get A Quote

Condensing Boilers and Dew Point: 'Tis the Season for

The byproducts created when burning natural gas to fire your boiler have a dew point of around 130ºF. This means that in order to get that condensation to appear on the heat exchanger, the water cycling through your radiators must be 130ºF or lower.

Get A Quote

Maximizing Boiler Plant Efficiency

• Thermal Efficiency – The combustion efficiency minus 2% = Lower dew point temperature Lower dew point temp. = Less condensation . 3/20/12 Condensing Boilers 21 Higher CO 2 =Higher Dew point =More Condensation 77 86 95 104 113 122 131 140 oF oC 25 30 35 40 45 50 55 60

Get A Quote

Consulting - Specifying Engineer | Controlling dew point

Nov 18, 2009 · In 2008, the ASHRAE Guide for Buildings in Hot and Humid Climates described a 55 F indoor dew point as a prudent maximum for mechanically cooled buildings, to avoid mold and moisture problems without excessive energy costs.10. In 2009, the U.S. Environmental Protection Agency adopted the 55 F maximum indoor dew point in its new advice to building designers, contractors, and …